Data captured: · Published: · Update delayed: this release is over 8 days old.
Photograph of the part · from aifitlab.com
1 / 1
1 / 1specs 18evidence [n]sources 1multiple values 5
No verified public price. Request a quotation from the seller.
1
Added to this browser's cart — no account, no contact details.
The prices here are distributors' listed figures, so this page does not take payment — a quote comes back with the real terms.
Shipping · lead time[value]
Specs.
Check before you order.
field · keyvaluesource sentencesourceEvidenceRetrieved · Changed
2 values for this fieldConfirm with the supplier.
Reduction ratioreduction_ratio
value
as printed 8080
source sentenceReduction Ratio 30 50 80 100
sourcehttps://aifitlab.com/products/py-technology-hbd-series-harmonic-reducer · Distributor page
EvidenceConflicting
Retrieved · Changed2026-08-28Changed —
Reduction ratioreduction_ratio
value
as printed 100100
source sentenceReduction Ratio 30 50 80 100
sourcehttps://aifitlab.com/products/py-technology-hbd-series-harmonic-reducer · Distributor page
EvidenceConflicting
Retrieved · Changed2026-08-28Changed —
Weightweight
valuemeasured at Reduction ratio Reduction ratio: 80 / 100
as printed 0.130.13 kg
source sentenceWeight (kg) 0.13 0.13 0.13 0.13
sourcehttps://aifitlab.com/products/py-technology-hbd-series-harmonic-reducer · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
4 values for this fieldConfirm with the supplier.
Rated torquerated_torque
valuemeasured at Reduction ratio 80
as printed 5.05 N·m
source sentenceRated Torque at 2000 r/min (Nm) 2.6 4.2 5.0 6.0
sourcehttps://aifitlab.com/products/py-technology-hbd-series-harmonic-reducer · Distributor page
EvidenceConflicting
Retrieved · Changed2026-08-28Changed —
Rated torquerated_torque
valuemeasured at Reduction ratio 100
as printed 6.06 N·m
source sentenceRated Torque at 2000 r/min (Nm) 2.6 4.2 5.0 6.0
sourcehttps://aifitlab.com/products/py-technology-hbd-series-harmonic-reducer · Distributor page
EvidenceConflicting
Retrieved · Changed2026-08-28Changed —
Rated torquerated_torque
valuemeasured at Reduction ratio 80
as printed 0.515.001 N·m
source sentenceRated Torque at 2000 r/min (Kgf·m) 0.27 0.43 0.51 0.61
sourcehttps://aifitlab.com/products/py-technology-hbd-series-harmonic-reducer · Distributor page
EvidenceConflicting
Retrieved · Changed2026-08-28Changed —
Rated torquerated_torque
valuemeasured at Reduction ratio 100
as printed 0.615.982 N·m
source sentenceRated Torque at 2000 r/min (Kgf·m) 0.27 0.43 0.51 0.61
sourcehttps://aifitlab.com/products/py-technology-hbd-series-harmonic-reducer · Distributor page
EvidenceConflicting
Retrieved · Changed2026-08-28Changed —
4 values for this fieldConfirm with the supplier.
Allowable start/stop torqueallowable_startstop_torque
valuemeasured at Reduction ratio 80
as printed 10.510.5 N·m
source sentencePermissible Peak Torque (Start/Stop) (Nm) 5.5 10 10.5 13.2
sourcehttps://aifitlab.com/products/py-technology-hbd-series-harmonic-reducer · Distributor page
EvidenceConflicting
Retrieved · Changed2026-08-28Changed —
Allowable start/stop torqueallowable_startstop_torque
valuemeasured at Reduction ratio 100
as printed 13.213.2 N·m
source sentencePermissible Peak Torque (Start/Stop) (Nm) 5.5 10 10.5 13.2
sourcehttps://aifitlab.com/products/py-technology-hbd-series-harmonic-reducer · Distributor page
EvidenceConflicting
Retrieved · Changed2026-08-28Changed —
Allowable start/stop torqueallowable_startstop_torque
valuemeasured at Reduction ratio 80
as printed 1.110.79 N·m
source sentencePermissible Peak Torque (Start/Stop) (Kgf·m) 0.55 1.0 1.1 1.3
sourcehttps://aifitlab.com/products/py-technology-hbd-series-harmonic-reducer · Distributor page
EvidenceConflicting
Retrieved · Changed2026-08-28Changed —
Allowable start/stop torqueallowable_startstop_torque
valuemeasured at Reduction ratio 100
as printed 1.312.75 N·m
source sentencePermissible Peak Torque (Start/Stop) (Kgf·m) 0.55 1.0 1.1 1.3
sourcehttps://aifitlab.com/products/py-technology-hbd-series-harmonic-reducer · Distributor page
EvidenceConflicting
Retrieved · Changed2026-08-28Changed —
2 values for this fieldConfirm with the supplier.
Allowable average load torqueallowable_average_load_torque
valuemeasured at Reduction ratio 80
as printed 8.68.6 N·m
source sentenceAllowable Average Load Torque (Nm) 4.0 6.6 8.6 10.5
sourcehttps://aifitlab.com/products/py-technology-hbd-series-harmonic-reducer · Distributor page
EvidenceConflicting
Retrieved · Changed2026-08-28Changed —
Allowable average load torqueallowable_average_load_torque
valuemeasured at Reduction ratio 80
as printed 0.878.532 N·m
source sentenceAllowable Average Load Torque (Kgf·m) 0.41 0.67 0.87 1.20
sourcehttps://aifitlab.com/products/py-technology-hbd-series-harmonic-reducer · Distributor page
EvidenceConflicting
Retrieved · Changed2026-08-28Changed —
4 values for this fieldConfirm with the supplier.
Peak torquepeak_torque
valuemeasured at Reduction ratio 80
as printed 2424 N·m
source sentenceInstantaneous Permissible Maximum Torque (Nm) 10.2 20 24 30
sourcehttps://aifitlab.com/products/py-technology-hbd-series-harmonic-reducer · Distributor page
EvidenceConflicting
Retrieved · Changed2026-08-28Changed —
Peak torquepeak_torque
valuemeasured at Reduction ratio 100
as printed 3030 N·m
source sentenceInstantaneous Permissible Maximum Torque (Nm) 10.2 20 24 30
sourcehttps://aifitlab.com/products/py-technology-hbd-series-harmonic-reducer · Distributor page
EvidenceConflicting
Retrieved · Changed2026-08-28Changed —
Peak torquepeak_torque
valuemeasured at Reduction ratio 80
as printed 2.423.54 N·m
source sentenceInstantaneous Permissible Maximum Torque (Kgf·m) 1.02 2 2.4 3
sourcehttps://aifitlab.com/products/py-technology-hbd-series-harmonic-reducer · Distributor page
EvidenceConflicting
Retrieved · Changed2026-08-28Changed —
Peak torquepeak_torque
valuemeasured at Reduction ratio 100
as printed 329.42 N·m
source sentenceInstantaneous Permissible Maximum Torque (Kgf·m) 1.02 2 2.4 3
sourcehttps://aifitlab.com/products/py-technology-hbd-series-harmonic-reducer · Distributor page
EvidenceConflicting
Retrieved · Changed2026-08-28Changed —
Backlashbacklash
valuemeasured at Reduction ratio Reduction ratio: 80 / 100
≤20
source sentenceBacklash (Arc sec) ≤20 ≤20 ≤20 ≤20
sourcehttps://aifitlab.com/products/py-technology-hbd-series-harmonic-reducer · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
specs 18, 18 shown
Source documents.
1 documents · 5 fields with several values
1 documents
aifitlab.com/products/py-technology-hbd-series-harmonic-reducerDistributor page · 18 valuesRetrieved 2026-08-28
DownloadSource files are not published yet: which documents may be published is undecided.
5 fields with several values
2026-08-28first collected · 1 sources
multiple values · 5Reduction ratio · Rated torque · Allowable start/stop torque · Allowable average load torque · Peak torque
Next update2026-10-01
Change history kept
Build a joint around this part.
Put a motor, a reducer and an encoder into the slots to see whether they combine.
Check joint combinationsJOINT · HBF-11 · C · Reducers
StatusNeeds checking
- Missing specs for the joint check
- No verdict: the specification keys it needs are not settled
To settle before a verdict
Supplier.
WRC 2026 Beijing exhibitors, and other suppliers.
PY TECHNOLOGYPY TECHNOLOGY
WRC2026-AFL-PYTECHNOLOGY
This supplier's parts 74Supplier page
Alternatives in preparation
Keep this part in your BOM.
When the BOM opens, you can collect parts and send one enquiry.