Data captured: · Published: · Update delayed: this release is over 8 days old.
Photograph of the part · from aifitlab.com
1 / 1
1 / 1specs 7evidence [n]sources 1
1000 HzSampling rate
1
Added to this browser's cart — no account, no contact details.
The prices here are distributors' listed figures, so this page does not take payment — a quote comes back with the real terms.
Shipping · lead time[value]
Specs.
Check before you order.
field · keyvaluesource sentencesourceEvidenceRetrieved · Changed
Measurement rangemeasurement_range
value
X/Y: same as HI12M0 (±250 to ±2000 °/s); Z: ±400 °/s (Default: ±400 °/s)
source sentenceMeasurement Range X/Y: same as HI12M0 (±250 to ±2000 °/s); Z: ±400 °/s (Default: ±400 °/s)
sourcehttps://aifitlab.com/products/hipnuc-hi12h-sensor · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Angular resolutionangular_resolution
value
<600 ppm (Typical: 850 ppm)
source sentenceAngular Resolution (RMS @ 100 °/s rotation) <600 ppm (Typical: 850 ppm)
sourcehttps://aifitlab.com/products/hipnuc-hi12h-sensor · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Sampling ratesampling_rate
value
as printed 1000 Hz1000 Hz
source sentenceSampling Rate 1000 Hz
sourcehttps://aifitlab.com/products/hipnuc-hi12h-sensor · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Measurement rangemeasurement_range
value
±3 / ±6 / ±12 / ±24 g (Default: ±12 g)
source sentenceMeasurement Range ±3 / ±6 / ±12 / ±24 g (Default: ±12 g)
sourcehttps://aifitlab.com/products/hipnuc-hi12h-sensor · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Measurement rangemeasurement_range
value
±2000 μT
source sentenceMeasurement Range ±2000 μT
sourcehttps://aifitlab.com/products/hipnuc-hi12h-sensor · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Noise levelnoise_level
value
0.19–0.45 μT
source sentenceNoise 0.19–0.45 μT
sourcehttps://aifitlab.com/products/hipnuc-hi12h-sensor · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Measurement rangemeasurement_range
value
-40 ~ 85 °C
source sentenceMeasurement Range -40 ~ 85 °C
sourcehttps://aifitlab.com/products/hipnuc-hi12h-sensor · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
specs 7, 7 shown
Source documents.
1 source the values were read from
1 documents
DownloadSource files are not published yet: which documents may be published is undecided.
No change
2026-08-28first collected · 1 sources
Next update2026-10-01
Change history kept
Build a joint around this part.
Put a motor, a reducer and an encoder into the slots to see whether they combine.
Check joint combinationsJOINT · HI12H · K · Sensing
StatusNeeds checking
- Missing specs for the joint check
- No verdict: the specification keys it needs are not settled
To settle before a verdict
Supplier.
WRC 2026 Beijing exhibitors, and other suppliers.
HiPNUCHiPNUC
WRC2026-AFL-HIPNUC
This supplier's parts 33Supplier page
Alternatives in preparation
Keep this part in your BOM.
When the BOM opens, you can collect parts and send one enquiry.