1000 HzSampling rate
0.19 µTNoise level
1
Added to this browser's cart — no account, no contact details.
The prices here are distributors' listed figures, so this page does not take payment — a quote comes back with the real terms.
Shipping · lead time[value]
Specs.
Check before you order.
field · keyvaluesource sentencesourceEvidenceRetrieved · Changed
Measurement rangemeasurement_range
value
±250°/s, ±500°/s, ±1000°/s, ±2000°/s, ±4000°/s (Default: ±2000°/s)
source sentenceMeasurement Range ±250°/s, ±500°/s, ±1000°/s, ±2000°/s, ±4000°/s (Default: ±2000°/s)
sourcehttps://aifitlab.com/products/hipnuc-hi13s-sensor · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Sampling ratesampling_rate
value
as printed 1000 Hz1000 Hz
source sentenceSampling Rate 1000 Hz
sourcehttps://aifitlab.com/products/hipnuc-hi13s-sensor · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Measurement rangemeasurement_range
value
±2g, ±8g, ±16g, ±32g (Default: ±16g)
source sentenceMeasurement Range ±2g, ±8g, ±16g, ±32g (Default: ±16g)
sourcehttps://aifitlab.com/products/hipnuc-hi13s-sensor · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Measurement rangemeasurement_range
value
±2000 μT
source sentenceMeasurement Range ±2000 μT
sourcehttps://aifitlab.com/products/hipnuc-hi13s-sensor · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Noise levelnoise_level
value
as printed 0.19 μT (Typical: 0.45 μT)0.19 µT
source sentenceNoise 0.19 μT (Typical: 0.45 μT)
sourcehttps://aifitlab.com/products/hipnuc-hi13s-sensor · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Measurement rangemeasurement_range
value
300 hPa ~ 1200 hPa
source sentenceMeasurement Range 300 hPa ~ 1200 hPa
sourcehttps://aifitlab.com/products/hipnuc-hi13s-sensor · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Measurement rangemeasurement_range
value
-40℃ ~ 85℃
source sentenceMeasurement Range -40℃ ~ 85℃
sourcehttps://aifitlab.com/products/hipnuc-hi13s-sensor · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
specs 7, 7 shown
Source documents.
1 source the values were read from
1 documents
DownloadSource files are not published yet: which documents may be published is undecided.
No change
2026-08-28first collected · 1 sources
Next update2026-10-01
Change history kept
Build a joint around this part.
Put a motor, a reducer and an encoder into the slots to see whether they combine.
Check joint combinationsJOINT · HI13S · K · Sensing
StatusNeeds checking
- Missing specs for the joint check
- No verdict: the specification keys it needs are not settled
To settle before a verdict
Supplier.
WRC 2026 Beijing exhibitors, and other suppliers.
HiPNUCHiPNUC
WRC2026-AFL-HIPNUC
This supplier's parts 33Supplier page
Alternatives in preparation
Keep this part in your BOM.
When the BOM opens, you can collect parts and send one enquiry.