Data captured: · Published: · Update delayed: this release is over 8 days old.
Photograph of the part · from aifitlab.com
1 / 1
1 / 1specs 10evidence [n]sources 1
1
Added to this browser's cart — no account, no contact details.
The prices here are distributors' listed figures, so this page does not take payment — a quote comes back with the real terms.
Shipping · lead time[value]
Specs.
Check before you order.
field · keyvaluesource sentencesourceEvidenceRetrieved · Changed
Laser wavelengthlaser_wavelength
valuemeasured at Rated voltage 12~30 VDC
as printed 905 nm905 nm
source sentenceLaser wavelength 905 nm
sourcehttps://aifitlab.com/products/olei-lr-16f-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Field of viewfield_of_view
valuemeasured at Rated voltage 12~30 VDC
-15° ~ +15°
source sentenceField of View (Vertical) -15° ~ +15°
sourcehttps://aifitlab.com/products/olei-lr-16f-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Field of viewfield_of_view
valuemeasured at Rated voltage 12~30 VDC
360°
source sentenceField of View (Horizontal) 360°
sourcehttps://aifitlab.com/products/olei-lr-16f-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Measurement rangemeasurement_range
valuemeasured at Rated voltage 12~30 VDC
0.5~45m @10% reflectivity 0.5~100m @80% reflectivity 0.5~100m @reflector
source sentenceMeasurement range 0.5~45m @10% reflectivity 0.5~100m @80% reflectivity 0.5~100m @reflector
sourcehttps://aifitlab.com/products/olei-lr-16f-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Weightweight
valuemeasured at Rated voltage 12~30 VDC
~800 g
source sentenceWeight ~800 g
sourcehttps://aifitlab.com/products/olei-lr-16f-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Ambient temperatureambient_temperature
valuemeasured at Rated voltage 12~30 VDC
-10 ~ 50 °C
source sentenceOperating temperature -10 ~ 50 °C
sourcehttps://aifitlab.com/products/olei-lr-16f-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Storage temperaturestorage_temperature
valuemeasured at Rated voltage 12~30 VDC
-20 ~ 60 °C
source sentenceStorage temperature -20 ~ 60 °C
sourcehttps://aifitlab.com/products/olei-lr-16f-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Rated voltagerated_voltage
value
12~30 VDC
source sentenceOperating voltage 12~30 VDC
sourcehttps://aifitlab.com/products/olei-lr-16f-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Vibration resistancevibration_resistance
valuemeasured at Rated voltage 12~30 VDC
IEC 60068-2-6:2007
source sentenceVibration resistance IEC 60068-2-6:2007
sourcehttps://aifitlab.com/products/olei-lr-16f-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Distance resolutiondistance_resolution
valuemeasured at Rated voltage 12~30 VDC
as printed 2 mm2 mm
source sentenceDistance resolution 2 mm
sourcehttps://aifitlab.com/products/olei-lr-16f-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
specs 10, 10 shown
Source documents.
1 source the values were read from
1 documents
DownloadSource files are not published yet: which documents may be published is undecided.
No change
2026-08-28first collected · 1 sources
Next update2026-10-01
Change history kept
Build a joint around this part.
Put a motor, a reducer and an encoder into the slots to see whether they combine.
Check joint combinationsJOINT · LR-16F · K · Sensing
StatusNeeds checking
- Missing specs for the joint check
- No verdict: the specification keys it needs are not settled
To settle before a verdict
Supplier.
WRC 2026 Beijing exhibitors, and other suppliers.
OLEIOLEI
WRC2026-AFL-OLEI
This supplier's parts 11Supplier page
Alternatives in preparation
Keep this part in your BOM.
When the BOM opens, you can collect parts and send one enquiry.