JOINTDEX

Data captured: · Published: · Update delayed: this release is over 8 days old.

Components › K · Sensing › Benewake
TF-UW500Add to cart
Photograph of the part · from aifitlab.comTF-UW5001 / 1
Benewake · Benewake

TF-UW500

K · Sensing · active · sources 3
specs 18evidence [n]sources 3
1 mmDistance resolution
1

Added to this browser's cart — no account, no contact details.

The prices here are distributors' listed figures, so this page does not take payment — a quote comes back with the real terms.

Shipping · lead time[value]

Specs.

Check before you order.

field · keyvaluesource sentencesourceEvidenceRetrieved · Changed
Repeatabilityrepeatability
value
< 1 cm @ 1σ (0.1 ~ 2m)
source sentenceRepeatability < 1 cm @ 1σ (0.1 ~ 2m)
sourcehttps://aifitlab.com/products/benewake-tf-uw500-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Field of viewfield_of_view
value
< 0.5°
source sentenceField of View (FoV) < 0.5°
sourcehttps://aifitlab.com/products/benewake-tf-uw500-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Input power supplyinput_power_supply
value
DC 5 ± 0.2 V
source sentencePower supply DC 5 ± 0.2 V
sourcehttps://aifitlab.com/products/benewake-tf-uw500-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Ambient temperatureambient_temperature
value
0 ℃ ~ +50 ℃
source sentenceOperating temperature 0 ℃ ~ +50 ℃
sourcehttps://aifitlab.com/products/benewake-tf-uw500-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Storage temperaturestorage_temperature
value
-20 ℃ ~ +70 ℃
source sentenceStorage temperature -20 ℃ ~ +70 ℃
sourcehttps://aifitlab.com/products/benewake-tf-uw500-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Protocolprotocol
value
UART / I2C (Can be switched by command)
source sentenceCommunication Interface UART / I2C (Can be switched by command)
sourcehttps://aifitlab.com/products/benewake-tf-uw500-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Baud ratebaud_rate
value
Default 115200 (Configurable)
source sentenceBaud rate Default 115200 (Configurable)
sourcehttps://aifitlab.com/products/benewake-tf-uw500-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Repeatabilityrepeatability
value
< 1 cm @ 1σ (0.1 ~ 2m)
source sentenceRepeatability < 1 cm @ 1σ (0.1 ~ 2m)
sourcehttps://robotopian.com/products/benewake-tf-uw500-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-09-01Changed —
Field of viewfield_of_view
value
< 0.5°
source sentenceField of View (FoV) < 0.5°
sourcehttps://robotopian.com/products/benewake-tf-uw500-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-09-01Changed —
Input power supplyinput_power_supply
value
DC 5 ± 0.2 V
source sentencePower supply DC 5 ± 0.2 V
sourcehttps://robotopian.com/products/benewake-tf-uw500-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-09-01Changed —
Ambient temperatureambient_temperature
value
0 ℃ ~ +50 ℃
source sentenceOperating temperature 0 ℃ ~ +50 ℃
sourcehttps://robotopian.com/products/benewake-tf-uw500-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-09-01Changed —
Storage temperaturestorage_temperature
value
-20 ℃ ~ +70 ℃
source sentenceStorage temperature -20 ℃ ~ +70 ℃
sourcehttps://robotopian.com/products/benewake-tf-uw500-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-09-01Changed —
Protocolprotocol
value
UART / I2C (Can be switched by command)
source sentenceCommunication Interface UART / I2C (Can be switched by command)
sourcehttps://robotopian.com/products/benewake-tf-uw500-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-09-01Changed —
Baud ratebaud_rate
value
Default 115200 (Configurable)
source sentenceBaud rate Default 115200 (Configurable)
sourcehttps://robotopian.com/products/benewake-tf-uw500-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-09-01Changed —
Distance resolutiondistance_resolution
value
as printed 1 mm1 mm
source sentenceDistance resolution 1 mm
sourcehttps://aifitlab.com/products/benewake-tf-uw500-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Distance resolutiondistance_resolution
value
as printed 1 mm1 mm
source sentenceDistance resolution 1 mm
sourcehttps://robotopian.com/products/benewake-tf-uw500-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-09-01Changed —
Repeatabilityrepeatability
value
< 1 cm @ 1σ
source sentence重复精度 < 1 cm @ 1σ
sourcehttps://www.benewake.com/TFUW500/index.html · Maker's document
EvidenceSourced
Retrieved · Changed2026-09-01Changed —
Ambient temperatureambient_temperature
value
0℃ ~ +50℃
source sentence工作温度 0℃ ~ +50℃
sourcehttps://www.benewake.com/TFUW500/index.html · Maker's document
EvidenceSourced
Retrieved · Changed2026-09-01Changed —
specs 18, 18 shown

Source documents.

3 sources the values were read from

3 documents
aifitlab.com/products/benewake-tf-uw500-lidarDistributor page · 8 valuesRetrieved 2026-08-28
robotopian.com/products/benewake-tf-uw500-lidarDistributor page · 8 valuesRetrieved 2026-09-01
benewake.com/TFUW500/index.htmlMaker's document · 2 valuesRetrieved 2026-09-01
DownloadSource files are not published yet: which documents may be published is undecided.
No change
2026-08-28first collected · 3 sources
Next update2026-10-01

Change history kept

Build a joint around this part.

Put a motor, a reducer and an encoder into the slots to see whether they combine.

Check joint combinations
JOINT · TF-UW500 · K · Sensing
StatusNeeds checking
  • Missing specs for the joint check
  • No verdict: the specification keys it needs are not settled

To settle before a verdict

Supplier.

WRC 2026 Beijing exhibitors, and other suppliers.

BenewakeBenewake
WRC2026-AFL-BENEWAKEwww.benewake.com · official
This supplier's parts 20Supplier page

Alternatives in preparation

Keep this part in your BOM.

When the BOM opens, you can collect parts and send one enquiry.