field · keyvaluesource sentencesourceEvidenceRetrieved · Changed
Frame rateframe_rate
valuemeasured at Rated voltage DC 5V~12V
1Hz~1000Hz (adjustable, default 100Hz)
source sentenceFrame rate 1Hz~1000Hz (adjustable, default 100Hz)
sourcehttps://aifitlab.com/products/benewake-tf02-pro-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Repeatabilityrepeatability
valuemeasured at Rated voltage DC 5V~12V
1σ:<2cm (0.1m~35m @90% reflectivity)
source sentenceRepeatability 1σ:<2cm (0.1m~35m @90% reflectivity)
sourcehttps://aifitlab.com/products/benewake-tf02-pro-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Field of viewfield_of_view
valuemeasured at Rated voltage DC 5V~12V
3°
source sentenceField of View (FoV) 3°
sourcehttps://aifitlab.com/products/benewake-tf02-pro-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Rated voltagerated_voltage
value
DC 5V~12V
source sentenceSupply voltage DC 5V~12V
sourcehttps://aifitlab.com/products/benewake-tf02-pro-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Power consumptionpower_consumption
valuemeasured at Rated voltage DC 5V~12V
≤1W
source sentencePower consumption ≤1W
sourcehttps://aifitlab.com/products/benewake-tf02-pro-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Peak currentpeak_current
valuemeasured at Rated voltage DC 5V~12V
as printed 300mA0.3 A
source sentencePeak current 300mA
sourcehttps://aifitlab.com/products/benewake-tf02-pro-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Ambient temperatureambient_temperature
valuemeasured at Rated voltage DC 5V~12V
-20°C ~ 60°C
source sentenceOperating temperature -20°C ~ 60°C
sourcehttps://aifitlab.com/products/benewake-tf02-pro-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Storage temperaturestorage_temperature
valuemeasured at Rated voltage DC 5V~12V
-30°C ~ 80°C
source sentenceStorage temperature -30°C ~ 80°C
sourcehttps://aifitlab.com/products/benewake-tf02-pro-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Weightweight
valuemeasured at Rated voltage DC 5V~12V
as printed 50g0.05 kg
source sentenceWeight (with cables) 50g
sourcehttps://aifitlab.com/products/benewake-tf02-pro-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Protocolprotocol
valuemeasured at Rated voltage DC 5V~12V
UART / I²C
source sentenceCommunication interface UART / I²C
sourcehttps://aifitlab.com/products/benewake-tf02-pro-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Frame rateframe_rate
valuemeasured at Rated voltage DC 5V~12V
1Hz~1000Hz (adjustable, default 100Hz)
source sentenceFrame rate 1Hz~1000Hz (adjustable, default 100Hz)
sourcehttps://robotopian.com/products/benewake-tf02-pro-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-09-01Changed —
Repeatabilityrepeatability
valuemeasured at Rated voltage DC 5V~12V
1σ:<2cm (0.1m~35m @90% reflectivity)
source sentenceRepeatability 1σ:<2cm (0.1m~35m @90% reflectivity)
sourcehttps://robotopian.com/products/benewake-tf02-pro-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-09-01Changed —
Field of viewfield_of_view
valuemeasured at Rated voltage DC 5V~12V
3°
source sentenceField of View (FoV) 3°
sourcehttps://robotopian.com/products/benewake-tf02-pro-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-09-01Changed —
Rated voltagerated_voltage
value
DC 5V~12V
source sentenceSupply voltage DC 5V~12V
sourcehttps://robotopian.com/products/benewake-tf02-pro-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-09-01Changed —
Power consumptionpower_consumption
valuemeasured at Rated voltage DC 5V~12V
≤1W
source sentencePower consumption ≤1W
sourcehttps://robotopian.com/products/benewake-tf02-pro-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-09-01Changed —
Peak currentpeak_current
valuemeasured at Rated voltage DC 5V~12V
as printed 300mA0.3 A
source sentencePeak current 300mA
sourcehttps://robotopian.com/products/benewake-tf02-pro-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-09-01Changed —
Ambient temperatureambient_temperature
valuemeasured at Rated voltage DC 5V~12V
-20°C ~ 60°C
source sentenceOperating temperature -20°C ~ 60°C
sourcehttps://robotopian.com/products/benewake-tf02-pro-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-09-01Changed —
Storage temperaturestorage_temperature
valuemeasured at Rated voltage DC 5V~12V
-30°C ~ 80°C
source sentenceStorage temperature -30°C ~ 80°C
sourcehttps://robotopian.com/products/benewake-tf02-pro-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-09-01Changed —
Weightweight
valuemeasured at Rated voltage DC 5V~12V
as printed 50g0.05 kg
source sentenceWeight (with cables) 50g
sourcehttps://robotopian.com/products/benewake-tf02-pro-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-09-01Changed —
Protocolprotocol
valuemeasured at Rated voltage DC 5V~12V
UART / I²C
source sentenceCommunication interface UART / I²C
sourcehttps://robotopian.com/products/benewake-tf02-pro-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-09-01Changed —
Distance resolutiondistance_resolution
valuemeasured at Rated voltage DC 5V~12V
as printed 1cm10 mm
source sentenceDistance resolution 1cm
sourcehttps://aifitlab.com/products/benewake-tf02-pro-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Distance resolutiondistance_resolution
valuemeasured at Rated voltage DC 5V~12V
as printed 1cm10 mm
source sentenceDistance resolution 1cm
sourcehttps://robotopian.com/products/benewake-tf02-pro-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-09-01Changed —
specs 22, 22 shown

Source documents.

2 sources the values were read from

2 documents
aifitlab.com/products/benewake-tf02-pro-lidarDistributor page · 11 valuesRetrieved 2026-08-28
robotopian.com/products/benewake-tf02-pro-lidarDistributor page · 11 valuesRetrieved 2026-09-01
DownloadSource files are not published yet: which documents may be published is undecided.
No change
2026-08-28first collected · 2 sources
Next update2026-10-01

Change history kept

Build a joint around this part.

Put a motor, a reducer and an encoder into the slots to see whether they combine.

Check joint combinations
JOINT · TF02-Pro · K · Sensing
StatusNeeds checking
  • Missing specs for the joint check
  • No verdict: the specification keys it needs are not settled

To settle before a verdict

Supplier.

WRC 2026 Beijing exhibitors, and other suppliers.

BenewakeBenewake
WRC2026-AFL-BENEWAKEwww.benewake.com · official
This supplier's parts 20Supplier page

Alternatives in preparation

Keep this part in your BOM.

When the BOM opens, you can collect parts and send one enquiry.