JOINTDEX

Data captured: · Published: · Update delayed: this release is over 8 days old.

Components › K · Sensing › Benewake
TFA1500-LAdd to cart
Photograph of the part · from aifitlab.comTFA1500-L1 / 1
Benewake · Benewake

TFA1500-L

K · Sensing · active · sources 2
specs 16evidence [n]sources 2
1

Added to this browser's cart — no account, no contact details.

The prices here are distributors' listed figures, so this page does not take payment — a quote comes back with the real terms.

Shipping · lead time[value]

Specs.

Check before you order.

field · keyvaluesource sentencesourceEvidenceRetrieved · Changed
Weightweight
valuemeasured at Rated voltage DC 3.0 ~ 5.0 V
as printed 11 ± 0.5 g0.011 kg
source sentenceWeight 11 ± 0.5 g
sourcehttps://aifitlab.com/products/benewake-tfa1500-l-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Ambient temperatureambient_temperature
valuemeasured at Rated voltage DC 3.0 ~ 5.0 V
-20 ~ +60 °C
source sentenceOperating temperature -20 ~ +60 °C
sourcehttps://aifitlab.com/products/benewake-tfa1500-l-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Storage temperaturestorage_temperature
valuemeasured at Rated voltage DC 3.0 ~ 5.0 V
-45 ~ +70 °C
source sentenceStorage temperature -45 ~ +70 °C
sourcehttps://aifitlab.com/products/benewake-tfa1500-l-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Rated voltagerated_voltage
value
DC 3.0 ~ 5.0 V
source sentenceSupply voltage DC 3.0 ~ 5.0 V
sourcehttps://aifitlab.com/products/benewake-tfa1500-l-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Vibration resistancevibration_resistance
valuemeasured at Rated voltage DC 3.0 ~ 5.0 V
5 to 50 to 5 Hz, 1 oct/min, 2.5 g
source sentenceVibration resistance 5 to 50 to 5 Hz, 1 oct/min, 2.5 g
sourcehttps://aifitlab.com/products/benewake-tfa1500-l-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Protocolprotocol
valuemeasured at Rated voltage DC 3.0 ~ 5.0 V
UART
source sentenceCommunication Interface UART
sourcehttps://aifitlab.com/products/benewake-tfa1500-l-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Baud ratebaud_rate
valuemeasured at Rated voltage DC 3.0 ~ 5.0 V
as printed 500000 bps500000 bps
source sentenceBaud rate 500000 bps
sourcehttps://aifitlab.com/products/benewake-tfa1500-l-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Weightweight
valuemeasured at Rated voltage DC 3.0 ~ 5.0 V
as printed 11 ± 0.5 g0.011 kg
source sentenceWeight 11 ± 0.5 g
sourcehttps://robotopian.com/products/benewake-tfa1500-l-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-09-01Changed —
Ambient temperatureambient_temperature
valuemeasured at Rated voltage DC 3.0 ~ 5.0 V
-20 ~ +60 °C
source sentenceOperating temperature -20 ~ +60 °C
sourcehttps://robotopian.com/products/benewake-tfa1500-l-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-09-01Changed —
Storage temperaturestorage_temperature
valuemeasured at Rated voltage DC 3.0 ~ 5.0 V
-45 ~ +70 °C
source sentenceStorage temperature -45 ~ +70 °C
sourcehttps://robotopian.com/products/benewake-tfa1500-l-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-09-01Changed —
Rated voltagerated_voltage
value
DC 3.0 ~ 5.0 V
source sentenceSupply voltage DC 3.0 ~ 5.0 V
sourcehttps://robotopian.com/products/benewake-tfa1500-l-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-09-01Changed —
Vibration resistancevibration_resistance
valuemeasured at Rated voltage DC 3.0 ~ 5.0 V
5 to 50 to 5 Hz, 1 oct/min, 2.5 g
source sentenceVibration resistance 5 to 50 to 5 Hz, 1 oct/min, 2.5 g
sourcehttps://robotopian.com/products/benewake-tfa1500-l-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-09-01Changed —
Protocolprotocol
valuemeasured at Rated voltage DC 3.0 ~ 5.0 V
UART
source sentenceCommunication Interface UART
sourcehttps://robotopian.com/products/benewake-tfa1500-l-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-09-01Changed —
Baud ratebaud_rate
valuemeasured at Rated voltage DC 3.0 ~ 5.0 V
as printed 500000 bps500000 bps
source sentenceBaud rate 500000 bps
sourcehttps://robotopian.com/products/benewake-tfa1500-l-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-09-01Changed —
Distance resolutiondistance_resolution
valuemeasured at Rated voltage DC 3.0 ~ 5.0 V
as printed 1 cm10 mm
source sentenceDistance resolution 1 cm
sourcehttps://aifitlab.com/products/benewake-tfa1500-l-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-08-28Changed —
Distance resolutiondistance_resolution
valuemeasured at Rated voltage DC 3.0 ~ 5.0 V
as printed 1 cm10 mm
source sentenceDistance resolution 1 cm
sourcehttps://robotopian.com/products/benewake-tfa1500-l-lidar · Distributor page
EvidenceSourced
Retrieved · Changed2026-09-01Changed —
specs 16, 16 shown

Source documents.

2 sources the values were read from

2 documents
aifitlab.com/products/benewake-tfa1500-l-lidarDistributor page · 8 valuesRetrieved 2026-08-28
robotopian.com/products/benewake-tfa1500-l-lidarDistributor page · 8 valuesRetrieved 2026-09-01
DownloadSource files are not published yet: which documents may be published is undecided.
No change
2026-08-28first collected · 2 sources
Next update2026-10-01

Change history kept

Build a joint around this part.

Put a motor, a reducer and an encoder into the slots to see whether they combine.

Check joint combinations
JOINT · TFA1500-L · K · Sensing
StatusNeeds checking
  • Missing specs for the joint check
  • No verdict: the specification keys it needs are not settled

To settle before a verdict

Supplier.

WRC 2026 Beijing exhibitors, and other suppliers.

BenewakeBenewake
WRC2026-AFL-BENEWAKEwww.benewake.com · official
This supplier's parts 20Supplier page

Alternatives in preparation

Keep this part in your BOM.

When the BOM opens, you can collect parts and send one enquiry.